• Back

  • ES-FA-11AA

    Item Detail ES and GM Series E-Stop and Guard Monitoring Safety Relays
    ES-FA-11AA
    ES-FA-11AA
    ES-FA-11AA

    Certifications

    • NISD NISD7 Vol1 Sec5
    • CE

    Compatible Amplifiers

    Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.

    Accessories to Complete Your System

    Add all or individual items to your cart. More options available below.

    Power
    AC/DC Universal
    IP Rating
    IP20
    Device Type
    Safety Relay
    In-Series Diagnostics
    No
    Safety Module Type
    Emergency Stop Module
    LCD Display
    No
    Expandable
    No
    Dimension (H x W x D in mm)
    84 x 22.5 x 118
    Relative Humidity
    90% @ 50° C
    Max Operating Temperature ( °C)
    50
    Input Operation
    Simultaneous or Concurrent
    Number of Safe Inputs
    1
    Input Configuration
    2 NC or 1 NC
    Safety Input - Dual Channel (Dry Contact)
    10-20 mA @ 12 V dc
    Safety Input - Reset
    20 mA @ 12 V dc (dry contact only)
    Independently Controlled Safe Outputs
    1
    Output Configuration
    2 NO
    Non Safe Output Configuration
    1 NC
    Non Safe Output Rating
    Relay - 7 A
    Safe Output Rating
    Relay - 7 A
    Splittable Safe Output
    No
    Mechanical Life (Operations in Millions)
    20
    Power Consumption
    2 W / 2 VA
    Recovery Time (ms)
    250
    Response Time (ms)
    25 (typical)
    Supply Voltage
    24 V ac/dc +/- 10%
    Terminal Type
    Screw
    Removable Terminals
    Yes
    Vibration
    10-55 Hz at 0.35 mm
    Electrical Life (Cycles @ VA)
    1,000,000 @ 450 VA
    PL Rating
    e
    Safety Category Rating
    4
    SIL Rating
    3
    SISTEMA
    PFHd = 5.1 x 10-10
    Safety Input - Single Channel
    40-100 mA @ 24 V ac/dc +/- 10%
    Input Resistance
    100 Ω max. per channel
    E-Stops/Rope Pulls
    Yes
    Safety Mat
    No
    Motor Speed
    No
    Muting
    No
    Gate Switch (NC/NC) Input
    Yes
    Gate Switch (NC/NO) Input
    No
    Gate Switch (OSSD) Input
    No
    Light Curtains/Scanner with EDM Input
    No
    Light Curtains/Scanner without EDM Input
    No
    Recovery Time
    250

    The following products are included with your order

    CAD Files

    Date
    Type
    Size
    GM-FA/ES-FA
    20 Apr 2022
    IGS
    1.6MB
    GM-FA/ES-FA
    20 Apr 2022
    STP
    1.1MB
    GM-FA/ES-FA
    22 Mar 2016
    DXF
    458K
    GM-FA/ES-FA
    22 Mar 2016
    PDF
    158K

    Literature

    Date
    Type
    Size
    ES-FA-9AA and ES-FA-11AA Safety Modules Instruction Manual
    25 Jul 2023
    DATA SHEET
    2.6MB

    Certification

    Date
    Type
    Size
    DoC for ES-FA-XAA, UM-FA-XA
    29 Dec 2022
    CERTIFICATION
    4.9MB
    ES-FA-11AA
    ES-FA-11AA
    Item Detail: ES and GM Series E-Stop and Guard Monitoring Safety Relays

    Certifications

    • NISD NISD7 Vol1 Sec5
    • CE