安全光栅系统

SGS 系列

SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications. They are available in Emitter/Receiver models capable of safeguarding over very long distances and in easy-to-deploy Active/Passive models that offer additional cost savings.

  • Models available with integral muting for entry/exit conveyors or palletizing cells
  • Heavy-duty aluminum housing for tough environments
  • Easy alignment and installation with on-board alignment lamp and indicators
  • Protective defined area heights of 500, 800, 900, or 1200 mm available
  • Up to 60 meter range available for perimeter guarding applications
  • Muting arm kits available to simplify end-of-line packaging applications
OPTIMIZE CONTROL SYSTEM PERFORMANCE
Remote I/O

技术文档

日期
类型
大小
SGS Safety Grid System (Emitter-Receiver Models) Instruction Manual
5 Oct 2023
产品说明书
7.7MB
SGS Safety Grid System (Active-Passive Models) Instruction Manual
5 Oct 2023
产品说明书
8.1MB
SGS Safety Grid System (Emitter-Receiver Models with Integral Muting) Instruction Manual
5 Oct 2023
产品说明书
7.5MB
SGS Safety Grid System (Active-Passive Models with Integral Muting) Instruction Manual
5 Oct 2023
产品说明书
7.9MB
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting
2 Aug 2021
说明书
633K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models)
16 Jan 2018
检验步骤
92K
SGS Safety Grid System Daily Checkout Procedure (Muting Models)
16 Jan 2018
检验步骤
121K
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models)
16 Jan 2018
检验步骤
121K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models)
16 Jan 2018
检验步骤
88K
SGSA-MCB Safety Grid System Connection Box
22 Sep 2017
说明书
460K
日期
类型
大小
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (French)
12/19/19
产品说明书
13.6MB
SGS Safety Grid System (Emitter/Receiver) -- Instruction Manual (French)
12/19/19
产品说明书
4.6MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (French)
12/19/19
产品说明书
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (French)
12/19/19
产品说明书
5.4MB
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (French)
01/04/19
检验步骤
82K
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (French)
01/04/19
检验步骤
115K
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (French)
08/06/18
说明书
583K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (French)
08/06/18
检验步骤
115K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (French)
08/06/18
检验步骤
86K
日期
类型
大小
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (German)
02/14/20
产品说明书
13.3MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (German)
02/14/20
产品说明书
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (German)
02/14/20
产品说明书
5.4MB
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (German)
02/14/20
产品说明书
4.6MB
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (German)
01/04/19
检验步骤
108K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (German)
01/04/19
检验步骤
75K
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (German)
08/06/18
说明书
582K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (German)
08/06/18
检验步骤
108K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (German)
08/06/18
检验步骤
78K
日期
类型
大小
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (Italian)
02/14/20
产品说明书
13.3MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (Italian)
02/14/20
产品说明书
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (Italian)
02/14/20
产品说明书
5.4MB
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (Italian)
02/14/20
产品说明书
4.6MB
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (Italian)
01/04/19
检验步骤
114K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (Italian)
01/04/19
检验步骤
82K
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (Italian)
08/06/18
说明书
581K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (Italian)
08/06/18
检验步骤
115K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (Italian)
08/06/18
检验步骤
83K

营销文档

日期
类型
大小
Safety Solutions Brochure
8 Apr 2025
产品手册
11.4MB
SGS Safety Grid System Flyer
7 Dec 2021
产品手册
1.8MB
日期
类型
大小
CN_Safety Solutions Brochure
安全解决方案
06/09/23
产品手册
14.8MB
SGS Safety Grids Sell Sheet
10/25/18
产品手册
2.4MB
汽车装配线上的区域和闸门防护
汽车装配线上的区域和闸门防护

一旦闸门打开并且光栅屏蔽,铰链就会停止传送带的运转。

弯管机的周边防护
弯管机的周边防护

经济实用的宽间距SGS安全光栅平台的安全光幕可保护工作区周边。光栅距离危险较远,如果人员或物体通过光栅,仍有足够时间停止运动。

保护码垛机上的输送机入口
保护码垛机上的输送机入口

码垛机的防护工作面临许多挑战,既要保证人员安全,又要保持高效生产。新的SGS安全光栅带屏蔽杆套件可以保护危险的机器人机械,同时允许箱子通过光栅而不停止生产。如果有箱子以外的东西通过光栅,屏蔽臂可以识别出来,并触发码垛机的机器停止。

SGS - 安全光栅系统 [视频]
SGS - 安全光栅系统

SGS 安全光栅系统是用于出入口和长距离周界防护应用的经济型多光束安全设备。

产品选型

加载中...

缩小结果范围

清除所有筛选器

Defined Area Height (mm)

  • (6)
  • (6)
  • (6)
  • (6)

Operating Distance (m)

  • (8)
  • (3)
  • (9)
  • (4)

Integral Muting

  • (12)

System Type

  • (12)
  • (4)
  • (8)

Resolution (mm)

  • (6)
  • (6)
  • (6)
  • (6)
查看全部 查看更少
选择的筛选器
  1. SGSSP4-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  2. SGSSP4-300Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  3. SGSSA4-400Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  4. SGSXP4-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  5. SGSXP2-500Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  6. SGSXP3-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  7. SGSB4-300

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    Mounting Hardware Ordered Separately

  8. SGSSA4-300Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  9. SGSB4-400

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
    Mounting Hardware Ordered Separately

  10. SGSSP3-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  11. SGSB3-400

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
    Mounting Hardware Ordered Separately

  12. SGSSA3-400Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  13. SGSXP4-300Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 6 to 60 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  14. SGSMP4-400Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  15. SGSSP2-500Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
    8-pin M12 Integral QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  16. SGSB2-500

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
    Mounting Hardware Ordered Separately

  17. SGSMA2-500Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  18. SGSMA4-300Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  19. SGSMP3-400Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  20. SGSSA2-500Q8

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 2; Resolution: 500 mm; Range: 0.5-8 m
    8-pin M12 Integral QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  21. SGSMA3-400Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 3; Resolution: 400 mm; Range: 0.5-8 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  22. SGSMA4-400Q12

    logo with r symbol

    SGS Safety Grid System, Active Transceiver
    Beams: 4; Resolution: 400 mm; Range: 0.5-8 m
    12-pin M12 QD; 5-pin M12 QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  23. SGSMP2-500Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  24. SGSMP4-300Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
    12-pin M12 QD (R), 8-pin (E); 5-pin M12 QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

添加至我的收藏夹
已添加